Snr Electronics

Control Panel

Leading Manufacturers, Exporters, Wholesaler and Retailer of SNR IP-DMS Control Panel and SNR-IP 2007 Control Panel from Sangli.

SNR IP-DMS Control Panel

Get Best Price
Business Type Manufacturer, Exporter, Supplier

Preferred Buyer From

Location Anywhere in India

Features : 

  • Micro Controller Based Technology
  • Motor Autostart Facility with setable on delay time.
  • RYB indication for each phase.
  • Protection from voltage unbalance, single phasing, overload, Drymn & also currcnt sensing SPP, (Push button fbr Setting)
  • LED Display for voltagc & ammeter & also indicator
  • 40 A power relay for ON/OFF switching.
  • Compact size.
  • 0/L. percentage can be setable from 110%to 170%.
  • N/L, % can be set from 90o/o to 50o/o Aftcr Dry run trip restart relay facility available (with variable time set). SPP/O/L. protection enable/disable facility. as per DMA
  • Micro Controller Based Technology
  • Motor Autostart with SPP.
  • Useful fbr 3 Ph. 1 to 5 H.P. Openwell,
  • Submersible, Monoblock pumps.
  • 16A BCH type 3 Pole contactor.
  • Auto/Manual Facility
  • Water level contractor facility also available.

 

Technical Specification :

  • Opelating voltage 
  • 220 to 460 VAC.50 Hz.
  • Drr Run trip tirning - 7 sec.
  • Or erload Electromagnetic Relay.
  • Drr Run setting -
  • 70% o of fiill load cutrent.
  • SPP Trip tin.re delay- 4 sec.
  • Voltage Unbalance Set. - 35 volts.
  • Voltage Sensing SPP.
Read More...


Yes! I am interested


SNR-IP 2007 Control Panel

Get Best Price
Business Type Manufacturer, Exporter, Supplier

Preferred Buyer From

Location Anywhere in India

Features : 

  • Microcontroller based technology.
  • Motor stafts automatically after time delay l/3/5 min.
  • Protection from voltage & current unbalance, single phasing.overload & dry run. (auto push button setting).
  • RYB indication for each phase,
  • Operates on lowvoltage (from250V)
  • Usefulfor 3 Ph. 1 to 6 H.P. Openwell, Submersible, Monoblock pumpsets.Separate indications for Timer, OK, SPP. Dry run & 0/L.
  • Auto Manual Facility.
  • Single phasing protection upto motor terminal.
  • 3 pole MCB formains ON/OFF & Shorl c ircuit protection

 

Technical Specification :

  • Opelating voltage
  • 220 to 460 VAC.50 Hz.
  • Drr Run trip tirning - 7 sec.
  • Or erload Electromagnetic Relay.
  • Drr Run setting -
  • 70% o of fiill load cutrent.
  • SPP Trip tin.re delay- 4 sec.
  • Voltage Unbalance Set. - 35 volts.
  • Voltage Sensing SPP.
Read More...